Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
9-1
9.1 Example without position control
9 Application examples
99000Application examplesApplication examples9-9.1Example without position control 9100Example without position control 9-
Evaluation of bit: "Unfeasible or single-channel signal from the
incremental encoder", without position control
Diagnosticbit 10: "Unfeasible or single-channel signal from the incre-
mental encoder" must be evaluated in the user program during opera-
tion in such a way that a set bit leads to a safety-related error reaction
(shutdown).
The connection point "Input Device OK" must be incorporated into the
application and evaluated in such a way that a shutdown occurs if the
connection point "Input Device OK"= 0.