6-1
6.1 General wiring guidelines
6 Commissioning
66000CommissioningCommissioning6-6.1General wiring guidelines6100General wiring guidelines6-
The wiring is defined in the circuit diagram of the PNOZmulti Configura-
tor.
Details of the input type, axis type and reset mode, plus the values for
standstill, speed monitoring and direction of rotation are also defined in
the PNOZmulti Configurator.
Please note:
` Information given in the "Technical details" must be followed.
` Use copper wire that can withstand 75 °C.
CAUTION!
The configurable switch-off delay when overspeed is reached
increases the reaction time of the system comprising base unit
and speed monitor by the stated value (see technical details).
This must not delay the transfer to a safe condition by more than
the permitted time. The configuration of the switch-off delay
must be considered in the risk assessment as regards hazards,
reaction time and safety distance.