2-1
2.1 Unit structure
2 Overview
22000OverviewOverview2-2.1Unit structure2100Unit structure2-
2.1.1 Scope of delivery
Scope of delivery2-Lieferumfang_Brck_774639_modul_BA
Expansion modulePNOZ ms3p HTL
Jumper 774 639
2.1.2 Unit features
Unit features2-Gerätemerkmale_Verwendung
Using the product PNOZ ms3p HTL:
Verwendung/Bildunterschrift_multi_Drehzahlwchter
Speed monitor for connection to a base unit from the configurable con-
trol system PNOZmulti
Geraetemerkmale_Zusatz BA Einleitung
The product has the following features:
Gertemerkmale
Monitoring of 2 independent axes
Connection per axis
1 incremental encoder
Measured variables:
standstill
Speed (8 values can be set)
Direction of rotation
Axis types, reset mode can be selected in the PNOZmulti Configura-
tor
Status indicators for
Supply voltage
Incremental encoder
Axis status, standstill and excess speed
Fault on the system
Incremental encoder connection technology:
RJ-45 female connector
Function to deactivate speed monitoring
Galvanic isolation between the connections X1, X12 and X22
Max. 4 speed monitors can be connected to the base unit