9 Project window
9 Project window
9.1 Setup
9.1.1 Basic setup
Regeneration resistor [ PBALRES ]
Internal The internal regeneration resistor is used.
External An external regeneration resistor, connected to the terminals +R
bext
and -R
B
, is
used.
Ohm
- PMCtendo DD5 and PMCprotego D only
Sets the value of the regeneration resistor in unit Ohm.
Max. Regeneration Power [
PBALMAX ]
Set the maximum Regen Power.
Max. Mains Voltage [
VBUSBAL ]
This parameter is used to adjust the regeneration and switch-off levels of the servo amplifiers to
suit the mains power supply voltage or the system conditions for multi-axis systems with
parallel-connected DC-link circuits.
Response to Loss of Input Phase [
PMODE ]
Handles the message „Phase missing“.
Hardware [
HVER ]
Display the version and revision level of the servo amplifier hardware.
Firmware [
VER ]
Display the version and revision level of the servo amplifier firmware.
Name [
ALIAS ]
Here you can assign a name (8 chars max.) to the servo amplifier.
Serial Number [
SERIALNO ]
Display the serial number of the servo amplifier.
Run Time [
TRUN ]
Display the operational time of the servo amplifier, saved at 8 min. intervals.
Page 18 User Manual for Setup Software PDrive